| Article number PAL |
0181100 | 0181110 | 0181120 | 0181130 | 0181140 |
| Article number NTSC |
0181200 | 0181210 | 0181220 | 0181230 | 0181240 |
| Description |
CCC Ex 95º CCC Ex 81º CCC Ex 70º CCC Ex 52º CCC Ex 44º |
| Horizontal angle |
95º 81º 70º 52º 44º |
| Vertical angle |
71º ... 53º 39º ... |
| CCD |
1/4 inch CCD Image sensor. |
| CCD total pixels |
PAL: 795(H) x 596(V), NTSC: 811(H) x 508(V). |
| Minimum illumination |
1,5 Lux (F1.2, 5600°K). |
| Resolution |
470 TVL / 580 TVL (Enhanced). |
| S/N ratio |
52dB ( MIN ) / 60dB ( TYP ) (AGC OFF). Ex II |
| A.E.S. |
1/50~1/100,000 sec. Ex II |
| Video output |
1,0V p-p composite video at 75 Ohm. Ex II |
| Gamma correction |
0,45 |
| Gain control |
AGC |
| White balance mode |
ATW / AWC Switchable. |
| White balance range |
3200 ~ 10000 ºK. |
| Mirror function |
REV. / NOR. Switchable via orange wire connected to 12V/DC +/- 3V. |
| Shock constancy |
Shock and vibration resistant for usage on offshore platform. |
| Weight |
0,44 kg, without cable. |
| Lensglass |
Chemically hardened, toughened, tempered floatglass, 5 to 7 times stronger thanordinary glass. |
| Housing |
Stainless steel 316L, IP68. |
| Camera bracket |
Camera bracket is made of glass reinforced polyamide, survives torque test:50 Nm at -40°C...+85°C. |
| Ambient temperature |
T4;-40°C<+75°C, T5;-40°C<+50°C, T6;-40°C<+35°C. |
| Cable |
Art. no 1220110, metric marker. 5,0 meters (+/-0,1m), the cable shall be fixedmounted. |
| Approvals |
EN 60079-0:2006, EN 60079-18:2004, EN 61241-0:2006, EN 61241-18:2004. |
| IEC 60079-0:2004, IEC 60079-18:2004, IEC 61241-0:2004, IEC 61241-18:2004. |
| Power |
+12V/DC +/- 15%, consumption 250mA heating on, 85mA heating off. Camera |
| must be connected to a fuse 250 mA slow blow. The breaking capacity of the fuse |
| must be in accordance with the prospective short circuit current of the supply. |
| Protection |
Automatic shutdown <11,1V/DC and >16,1V/DC Protection against extreme |
| voltage 28V/DC (500 hrs.) With Ferrite T filter protection against spikes, load- |
| dumps, ripples. |
| Notes: |
Electrical connections shall only be done by qualified Ex engineers following the |
| latest ATEX regulations. Us accepts no liability for mistakes, faults or |
| damages due to wrong voltage connection. Zenerbarriers and fuses are not |
| included, should be applied by installer. |